FORM 3.2 SUPPLEMENTAL ELECTRIC HOUR METERS (HOUR METERS)
To be Filed in Compliance with the AMENDED RULES GOVERNING THE MEASUREMENT OF TRIBUTARY GROUND WATER DIVERSIONS LOCATED IN THE ARKANSAS RIVER BASIN (AS FURTHER AMENDED) AND MEASUREMENT RULE POLICIES.

ELECTRIC HOUR METER (HOUR METER) VERIFICATION
For HOUR METERS:
1. 2. 3. 4. 5. Complete FORM 3.2 through "Calculations, notes, times, etc., used to determine Discharge, Q, in GPM." Complete this page only for HOUR METER VERIFICATION. SIGNATURES are required on FORM 3.2. A REQUEST FOR VARIANCE APPROVAL is required. FORM 3.2 and this FORM must be submitted together, along with the REQUEST FOR VARIANCE APPROVAL.

HOUR METER PROPERTIES:
Manufacturer: Model No.: Multiplier: Meter Units: No. of Rotating Digits:
Include all rotating digits Include leading zeros

SN:

INSTALLED METER Reading on Date of Test:

HOUR METER VERIFICATION:
INSTALLATION VERIFICATION:
HOUR METER is: HOUR METER is: Non-Resettable Yes ... No ..... Sealed with a crimp seal Yes.... No .... No .... No ....

Clearly visible and outside of electrical cabinets and/or structures Yes....

Crimp-Connected TO THE Power Supply Line WIRING from HOUR METER to POWER SUPPLY is: AND Yes.... Continuous with no connections or splices

HOUR METER ELAPSED TIME VERIFICATION:
STOP WATCH ELAPSED TIME INSTALLED HOUR METER ELAPSED TIME

AVG TIMET: VERIFICATION = FACTOR
If Verification Factor is:

AVG TIMEI: =

AVG TIMET AVG TIMEI
0.950 to 1.050 < 0.950 OR > 1.050

Correction Factor must be shown to the nearest 0.000.

HOUR METER is acceptable. HOUR METER is NOT acceptable. WELL OWNER/USER will be required to install TFM.

ARKFORM3_2SUPP.DOC

UPDATED: 02/15/06

FORM 3.2 SUPPLEMENTAL PRIVATELY-OWNED ELECTRIC METERS (SLAVE METERS)
To be Filed in Compliance with the AMENDED RULES GOVERNING THE MEASUREMENT OF TRIBUTARY GROUND WATER DIVERSIONS LOCATED IN THE ARKANSAS RIVER BASIN (AS FURTHER AMENDED) AND MEASUREMENT RULE POLICIES.

PRIVATELY-OWNED ELECTRIC METER (SLAVE METER) VERIFICATION
For SLAVE METERS:
1. 2. 3. 4. 5. Complete FORM 3.2 through "Calculations, notes, times, etc., used to determine Discharge, Q, in GPM." Complete this page only for SLAVE METER VERIFICATION. SIGNATURES are required on FORM 3.2. A REQUEST FOR VARIANCE APPROVAL is required. FORM 3.2 and this FORM must be submitted together, along with the REQUEST FOR VARIANCE APPROVAL.

SLAVE METER PROPERTIES:
Manufacturer: Model No.: Multiplier: Meter Units: No. of Rotating Digits:
Include all rotating digits Include leading zeros 2.4:1(2.4) ...... 400:5(80) ...... Other (specify) 800:5(160) ........ Other (specify)

SN:

INSTALLED METER Reading on Date of Test:
Voltage/Potential None ..... Transformer Factor (PT): Current Transformer None ..... Factor (CT): 2.5:1 (2.5) ... 200:5(40) ....

Kh factor:

Pkh = Kh x PT x CT =

DETERMINATION OF POWER DEMAND: (MINIMUM OF THREE TESTS)
Disk Revolutions Seconds Rate (Rev/Sec) Disk Revolutions Seconds Rate (Rev/Sec)

Average Rate: POWER DEMAND, P = Average Rate x 3.6 x Pkh =

KW

to nearest 0.0

CALCULATION OF POWER CONSUMPTION COEFFICIENT:

PCC =

5433 x P Q

=

kWH/AF

PCC must be shown to the nearest 0.0

ARKFORM3_2SUPP.DOC